Talk to an Expert ↗
Genome Heat Cool Skid

Control the thermal conditions your process depends on.

Circulate heated or cooled thermal fluid through process equipment with a compact control skid configured around your operating needs.

Choose a 15 kW or 30 kW heating package. Cooling connects to a separately selected external chiller, with the final configuration confirmed around thermal load, utilities, controls, and connected equipment.

Genome Heat Cool Skid full system on a clean white background

Genome Heat Cool Skid full-system view. Final supplied equipment depends on the selected project configuration.

How it fits the process

Connect heating, cooling, and circulation.

The skid manages thermal fluid used to control process temperatures. The exact connected equipment, external chiller, flow requirements, controls, and utility interfaces are confirmed for the selected package.

01 / RECEIVE

Receive cooling.

Chilling fluid enters from a compatible external chiller selected around the process load and operating conditions.

02 / CONDITION

Condition the thermal fluid.

The skid supports heating and cooling control across the listed temperature range, subject to the final configuration and connected equipment.

03 / CIRCULATE

Circulate to the process.

Heated or cooled thermal fluid is delivered to the connected vessel or process equipment that requires temperature control.

Heating options

Match the heating package to the process.

Two heating-capacity options are currently documented. The applicable electrical supply, controls, external chiller, and process load are confirmed before the final package is selected.

HEATING OPTION

15 kW

A documented heating-capacity option for applications whose thermal load and available electrical supply align with this package.

HEATING OPTION

30 kW

The higher documented heating-capacity option, selected when the connected process and electrical plan require additional heating capacity.

Full system and components

Review the package from the system level to the connection details.

Use the arrows or thumbnails to move through the cleaned product photographs. Select the main image to open a larger view, then continue through the gallery.

The title and description beneath each image identify the full system or the component detail shown.

Specifications

Genome Heat Cool Skid specification table.

The values below summarize the currently documented configuration. Final electrical, cooling, controls, dimensions, and integration requirements are confirmed for the selected project package.

SpecificationListed value
Equipment designThermal-fluid heating and cooling control system
Heating-capacity options15 kW or 30 kW
Temperature range−40 to 150°C
Thermal-fluid volume40 L
Footprint2 ft × 2 ft
Heated surface area2 m²
Maximum allowable working pressure15 psi
Cooling supplyExternal chiller connection
Hazardous-location optionC1D1 availability is listed; confirm the final package
Heat Cool Skid

Thermal-fluid control and circulation.

The skid receives chilling fluid from an external chiller, then circulates heated or cooled thermal fluid to the connected process equipment.

Related temperature-control product

Genome Heat Pump

The product workbook treats the Genome Heat Pump as a separate product. Its current capacity, efficiency, controls, operating range, installation requirements, and commercial positioning still need Senti confirmation before a separate product page is prepared.

Plan temperature control with the connected equipment in mind.

Share the vessel or process equipment, temperature range, thermal load, available utilities, and external-chiller requirements for your project.