Talk to an Expert ↗
System Integration & Support

Improve the system you already have—without assuming the answer is a complete replacement.

A slow recovery stage, undersized thermal loop, awkward changeover, disconnected control, or difficult handoff can hold back otherwise capable equipment.

Start with the current process and the measured constraint. Then plan the equipment, facility interfaces, installation, and operator support around what needs to work together.

Three-dimensional facility and equipment layout used for extraction-system planning

Integration planning connects equipment, controls, utilities, room, and operator workflow.

01 / Start with the current system

The best upgrade addresses the stage that limits the line.

Before selecting hardware, compare cycle time, waiting, changeovers, recovery, temperature control, controls, and downstream queues across the complete workflow. The recurring constraint—not the loudest single problem—should guide the scope.

01

Connections & changeovers

Hoses, valves, staging, transfers, and setup time can leave equipment waiting between otherwise productive cycles.

02

Recovery capacity

Slow solvent recovery can delay vessel turnover, solvent availability, and the next extraction run even when the extractor has capacity.

03

Thermal performance

Heating or chilling that cannot keep pace with the process can extend recovery, hold times, and transitions between operating conditions.

04

Controls & handoffs

Separate controls, unclear alarms, manual workarounds, filtration, or downstream queues can limit the useful output of the line.

A faster component is not automatically a faster operation. Confirm how a proposed change affects the stages before and after it, required safeguards, product quality, utilities, and the next likely constraint.

02 / Review the interfaces

Treat the upgrade as part of one operating system.

The equipment must fit the process, room, utilities, controls, safety requirements, maintenance plan, operator workflow, and documentation. Review those interfaces together before finalizing the integration path.

PROCESS

Product & workflow

Define the material, product target, sequence, batch size, cycle time, quality requirements, and handoffs the integrated line must support.

EQUIPMENT

Mechanical connections

Review sanitary piping, hoses, vessels, fittings, pumps, pressure and temperature limits, service access, cleaning, and compatible materials.

FACILITY

Room & utilities

Confirm floor space, access, electrical supply, compressed air, heating and cooling, ventilation, drains, service clearances, and planned growth.

CONTROLS

Signals & operating logic

Map the current control panels, interlocks, alarms, permissives, data needs, manual steps, and responsibilities between connected equipment.

PEOPLE

Operators & maintenance

Include startup, changeover, cleaning, inspection, troubleshooting, preventive maintenance, training, and the handoff between operating roles.

DOCUMENTATION

Scope & handoff

Identify the drawings, specifications, manuals, SOP inputs, training materials, acceptance checks, and project records required for the selected scope.

Project responsibilities are scope-specific. The facility’s qualified engineering, safety, quality, regulatory, and trade teams remain responsible for applicable codes, hazardous-location requirements, permits, SOPs, validation, approvals, and safe operation.

03 / A practical project path

Move from a recurring problem to a defined integration scope.

The exact services depend on the project. A useful path keeps operating evidence, equipment decisions, facility interfaces, and the handoff connected.

Example extraction-equipment project planning and installation timeline

Example project-planning reference. Actual stages, responsibilities, approvals, and timing vary by scope.

01

Baseline

Document the current system, production target, actual timing, recurring constraint, and operating context.

02

Concept

Compare targeted integration pathways and define what each option must improve, connect, and preserve.

03

Plan

Develop the applicable layout, connection, utility, controls, documentation, schedule, and responsibility plan.

04

Integrate

Coordinate installation, connection checks, startup readiness, and commissioning activities for the agreed scope.

05

Handoff

Support operator orientation, project records, follow-up questions, and a review of the agreed operating measures.

How Evolved helps

Match the support scope to the constraint.

Bring the installed equipment, process map, facility context, and target into the same conversation. Depending on the project, the path may involve one targeted integration, several connected upgrades, or a broader facility and controls scope.

TARGETED CAPABILITY

Equipment integrations

Review recovery, temperature control, filtration, crystallization, vessels, pumps, controls, or other supporting equipment around assets already on the floor.

INSTALLED EQUIPMENT

Existing-system upgrades

Examine connections, changeovers, recovery, thermal capacity, controls, and workflow before choosing a retrofit or replacement pathway.

FACILITY INTERFACES

Layout, utilities & controls planning

Coordinate applicable floor plans, equipment arrangement, process connections, utilities, controls, service access, and project responsibilities before installation.

STARTUP & HANDOFF

Commissioning and operator support

Support the agreed startup checks, equipment handoff, operator orientation, troubleshooting pathways, and follow-up review for the selected scope.

Prepare the first conversation

Bring the current line—not a predetermined equipment list.

You do not need a perfect engineering study. A clear record of the current operation gives the team a better place to begin.

Document these six things:

  1. Installed equipment: manufacturer, model, configuration, age, available drawings, and known limitations.
  2. Production target: material, product, batch or shift target, quality requirements, and planned growth.
  3. Current workflow: every major process step, transfer, changeover, cleaning step, and downstream handoff.
  4. Observed constraint: where equipment, material, solvent, utilities, or people repeatedly wait.
  5. Facility context: room, access, utilities, controls, hazardous-location requirements, and planned construction.
  6. Operating evidence: actual cycle time, downtime, maintenance history, rework, alarms, and the effect on completed output.
Free resource

See how bottlenecks can be addressed around existing equipment.

SYSTEM-UPGRADE WEBINAR

Triple Your Extraction Throughput: Upgrading Existing Systems

Explore connections and changeovers, solvent recovery, thermal capacity, and retrofit pathways around installed extraction equipment, including a discussion of Bizzy, Precision, and ETS systems.

The webinar title is not a universal performance promise. Results depend on the baseline system, selected integration, utilities, process conditions, and operating practices.

Bring us the system you have and the problem you need to solve.

Share the current equipment, production target, recurring constraint, and facility context. Start with the evidence—not an assumed replacement plan.